Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Case Stud Transp Policy ; 10(1): 647-656, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36157268

RESUMO

We address the impact of the COVID-19 crisis on the US airlines market and discuss the benefits and limitations of current business models in a context of increasing socio-economic uncertainty and stringent environmental regulations. Drawing our data from the Bureau of Transportation Statistics and 10-K/A reports, we undertook an exploratory study of the performance of the 10 main passenger airlines in their domestic operation during one year. We found that, although major losses occurred industry-wide, ultra-low-cost and low-cost airlines fared better than full-service network carriers did in terms of financial performance. We argue, nevertheless, that such apparently successful business models are not necessarily adaptive to address future industry changes.

2.
Diagnostics (Basel) ; 11(6)2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34073652

RESUMO

OBJECTIVE: The aims of this study are to analyze the role of artery-vein ratio AVR assessment using VesselMap 2 software (Imedos Systems) and cardiovascular risk evaluation by means of REGICOR in the prediction of silent brain infarction (SBI) in middle-age hypertensive patients from the ISSYS study. MATERIAL AND METHODS: A cross-sectional study with 695 patients with hypertension aged 50 to 70 years who participated in the project Investigating Silent Strokes in HYpertensives: a Magnetic Resonance Imaging Study (ISSYS), was conducted in two Primary Care Centres of Barcelona. Participants agreed to a retinography and an MRI to detect silent brain infarction (SBI). The IMEDOS software was used for the semiautomatic caliber measurement of retinal arteries and veins, and the AVR was considered abnormal when <0.66. The REGICOR score was calculated for all patients. RESULTS: Multivariate logistic regression analysis was used to evaluate the impact of AVR and REGICOR scores on SBI. The OR (odds ratio) for a high REGICOR score and an abnormal AVR were 3.16 and 4.45, respectively. When analysing the interaction of both factors, the OR of an abnormal AVR and moderate REGICOR score was 3.27, whereas with a high REGICOR score it reached 13.07. CONCLUSIONS: The measurement of AVR in patients with hypertension and with a high REGICOR score can contribute to the detection of silent brain infarction.

3.
Aten. prim. (Barc., Ed. impr.) ; 52(6): 410-417, jun.-jul. 2020. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-201997

RESUMO

OBJETIVO: La hipertensión arterial es una de las enfermedades más prevalentes en la población general adulta. Su importancia reside en las complicaciones que ocasiona en el lecho vascular de órganos diana como riñón, corazón, cerebro y ojo. El objetivo de este trabajo es evaluar la concordancia en la lectura e interpretación de retinografías de pacientes hipertensos realizadas por médicos de familia y por oftalmólogos. MATERIAL Y MÉTODOS: Es un estudio transversal multicéntrico que contó con 976 pacientes hipertensos de 50 a 70 años, participantes del proyecto «Investigating Silent Strokes in HYpertensives: a Magnetic Resonance Imaging Study» (ISSYS) realizado en centros de Atención Primaria de Barcelona y que accedieron a realizarse una retinografía. Seis médicos de familia y 2 oftalmólogos valoraron la presencia de lesiones en la retina mediante los criterios de Keith-Wagener-Barker. RESULTADOS: Se analizó la concordancia Kappa inter- e intraobservador de las lecturas. La valoración de las retinografías en condiciones habituales de práctica clínica obtuvo un alto componente subjetivo, con valores de concordancia inter- e intraobservador pobres-bajos en los criterios de Keith-Wagener-Barker. Solo la valoración de los microaneurismas presentó una concordancia moderada; la ratio arteria/vena fue la menos concordante. Se recomienda la utilización de sistemas de lectura objetivos en la valoración de retinografías en pacientes hipertensos. CONCLUSIONES: La valoración de las retinografías en condiciones habituales de práctica clínica tiene un alto componente subjetivo que se refleja en unos valores de concordancia inter- e intraobservador pobres o bajos. Se recomienda la utilización de sistemas de lectura objetivos en la valoración de retinografías en pacientes hipertensos


OBJECTIVE: High blood pressure is one of the most prevalent diseases in general adult population. Its importance lies in the complications it causes in target organs such as kidney, heart, brain and eye. The aim of this work is to evaluate the agreement in the evaluation and interpretation of retinographies of hypertensive patients by family doctors and ophthalmologists. MATERIAL AND METHODS: This is a multicentric cross-sectional study in which 976 hypertensive patients from 50 to 70 years old were involved. They were participants of the «Investigating Silent Strokes in Hypertensives: a Magnetic Resonance Imaging Study» (ISSYS project) carried out in primary care centers of Barcelona and who agreed to undergo retinography. Six family physicians and 2 ophthalmologists evaluated the presence of retinal lesions through the Keith-Wagener-Barker criteria. RESULTS: The inter/intra-observer Kappa concordance of the evaluations was analyzed. The evaluation of the retinographies under the usual conditions of clinical practice obtained a high subjective component with slight and fair intra-observer concordance values in the Keith-Wagener-Barker criteria. Only the assessment of the microaneurysms showed a moderate concordance and the ratio artery/vein was the worst concordant. CONCLUSIONS: The evaluation of the retinographies in habitual conditions of clinical practice has a high subjective component that is reflected in slight and fair inter-intraobserver concordance values. The use of objective reading systems in the assessment of retinography in hypertensive patients would be useful


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Retinopatia Hipertensiva/diagnóstico por imagem , Atenção Primária à Saúde , Oftalmoscopia/métodos , Médicos de Família , Oftalmologistas , Retinopatia Hipertensiva/etiologia , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico , Índice de Gravidade de Doença , Fundo de Olho , Reprodutibilidade dos Testes
4.
Aten Primaria ; 52(6): 410-417, 2020.
Artigo em Espanhol | MEDLINE | ID: mdl-31694763

RESUMO

OBJECTIVE: High blood pressure is one of the most prevalent diseases in general adult population. Its importance lies in the complications it causes in target organs such as kidney, heart, brain and eye. The aim of this work is to evaluate the agreement in the evaluation and interpretation of retinographies of hypertensive patients by family doctors and ophthalmologists. MATERIAL AND METHODS: This is a multicentric cross-sectional study in which 976 hypertensive patients from 50 to 70 years old were involved. They were participants of the «Investigating Silent Strokes in Hypertensives: a Magnetic Resonance Imaging Study¼ (ISSYS project) carried out in primary care centers of Barcelona and who agreed to undergo retinography. Six family physicians and 2 ophthalmologists evaluated the presence of retinal lesions through the Keith-Wagener-Barker criteria. RESULTS: The inter/intra-observer Kappa concordance of the evaluations was analyzed. The evaluation of the retinographies under the usual conditions of clinical practice obtained a high subjective component with slight and fair intra-observer concordance values in the Keith-Wagener-Barker criteria. Only the assessment of the microaneurysms showed a moderate concordance and the ratio artery/vein was the worst concordant. CONCLUSIONS: The evaluation of the retinographies in habitual conditions of clinical practice has a high subjective component that is reflected in slight and fair inter-intraobserver concordance values. The use of objective reading systems in the assessment of retinography in hypertensive patients would be useful.


Assuntos
Retinopatia Hipertensiva , Adulto , Idoso , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico , Humanos , Retinopatia Hipertensiva/diagnóstico por imagem , Pessoa de Meia-Idade , Atenção Primária à Saúde , Reprodutibilidade dos Testes
5.
Harv Bus Rev ; 84(9): 135-40, 142, 144-5 passim, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16967627

RESUMO

PC maker Lenovo started out as a distributor of equipment made by IBM and other companies; now it has formed a joint venture with IBM and will eventually affix its own logo to its computers. Shanghai Automotive Industry Corporation (SAIC) started out manufacturing vehicles for Volkswagen and GM; now it's preparing to sell its own cars in China, Europe, and North America. Lenovo and SAIC represent a host of formerly anonymous makers of brand-name products that are breaking out of their defined roles and pushing the brands themselves aside. In this article, the authors explore the double-edged relationships original equipment manufacturers (OEMs) forge with their contract manufacturers (CMs). On the one hand, an OEM can reduce its labor costs, free up capital, and improve worker productivity by outsourcing all the manufacturing of a product. The company can then concentrate on value-adding activities--research and development, product design, and marketing, for instance. On the other hand, an OEM that retains a contract manufacturer may find itself immersed in a melodrama replete with promiscuity (the ambitious CM pursues liaisons with other OEMs), infidelity (the OEM's retailers and distributors shift their business to the upstart CM), and betrayal (the brazen CM transmits the OEM's intellectual property to the OEM's rivals or keeps it for itself when the contract is up). OEMs cannot simply terminate their outsourcing arrangements--they need contract manufacturers in order to keep specializing, adding value, and staying competitive. But OEMs can manage these relationships so that they don't become weak or the CMs too strong. Doing so requires modesty about revealing trade secrets; caution about whom one consorts with; and a judicious degree of intimacy, loyalty, and generosity toward partners and customers.


Assuntos
Comércio , Contratos , Competição Econômica , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...